Bioactive Biphasic Synthetic Bone Graft Substitute

    MBCP Sticks are biphasic calcium phosphate ceramics composed of hydroxyapatite (HA) and tricalcium phosphate (TCP), developed from MBCP Technology.
    MBCP Sticks are indicated to augment or substitute bone graft in non-loadbearing clinical applications.

    MBCP™ Technology’s Key Features

    Osteoconductive

    Provides a matrix for new bone growth

    Molecular mixture of HA and TCP

    HA alone resorbs too slowly while TCP resorbs too fast. Bi-phasic HA and TCP allow for a resorption rate similar to that of human bone.

    70% porosity, similar to cancellous bone

    Interconnected network of macropores and micropores that enables the colonization of bone cells and biological fluid uniformly within the matrix.

    Bioactive

    For ionic exchange: TCP dissolution and bone crystal precipitation. Newly bioactive interface with bone cells.

    Macroporosity

    Macropores are a network of interconnected spaces that promote the biological infiltration and cellular colonization by osteoblasts and osteoclasts.

    Microporosity

    Micropores are the intercrystalline spaces where dissolution and recrystallisation occurs.

    >30 years of clinical experience

    Host bone formation is systematically demonstrated.

    Safe

    100% synthetic – 5 years shelf life.

    Concept
    1. Daculsi G. and al, Current State-of-the-Art of Biphasic Calcium Phosphate Bioceramics, Journal of Materials Science, Vol 14, No 3, pp195-200. (2003)
    2. Daculsi G.,Jegoux F. and Layrolle P. «The micro macroporous biphasic calcium phosphate concept for bone reconstruction and tissue engineering», Advanced Biomaterials: Fundamentals, Processing, and Application, B. Basu. et al., J. Wiley and sons Inc., pp101-141 (2009)
    3. Ransford A.O. and al., “Synthetic porous ceramic compared with autograft in scoliosis surgery. A prospective, randomized study of 341 patients.” J Bone Joint Surg Br, 80(1): 13-8. (1998)
    4. Gouin F., Delecrin J. , Passuti N., Touchais S., Poirier P., Bainvel J., “Biphasic macroporous calcium phosphate ceramic bone substitute for filling bone defects: A report of 23 cases.” Revue de Chirurgie Orthopedique: 81; 59–65 (1995)
    5. Daculsi G. , Corlieu P. , Bagot D’Arc M., Gersdorff M., “Macroporous biphasic calcium phosphate efficiency in mastoid cavity obliteration: experimental and clinical findings.” Annals of Otology, Rhinology & Laryngology: 101(8); 669–674 (1992).
    6. Daculsi G. , Passuti N., Martin S., Deudon C. , Legeros R., Raher S., “Macroporous calcium phosphate ceramic for long bone surgery in humans and dogs. Clinical and histological study.” Journal of Biomedical Materials Research: 24; 379–396 (1990).

    Rigid fixation techniques may be required to assure rigid stabilization of the defect in all planes.
    MBCP™ must not be used for femoral or tibial osteotomies without appropriate opening osteotomy system devices, plates and screws.
    Maximum contact between the product and the recipient bone must be established.
    The implantation in a revision surgical site containing non-resorbable fragments of material (e.g. polyethylene ligament waste, carbon fibers) is not recommended.
    As with any surgical procedure, care should be exercised in treating individuals with preexisting conditions that may affect the success of the surgical procedure. This includes (but is not limited to) individuals with long-term steroidal therapy or treatment acting on the calcium or phosphorus metabolism.
    MBCP™ is radiopaque until resorbed. Radiopacity may mask underlying pathological conditions. Radiopacity may also make it difficult to radiographically assess the ingrowth of new bone.
    MBCP™ is intended for use by surgeons familiar with bone grafting and rigid fixation techniques.
    MBCP™ has not been tested on pregnant women. The risk of health has not been established.

    • ISO 13485
    • Read the instructions for use
    • MBCP™ is supplied sterile and CE-marked as a Class III Medical Device according to Directive EEC/93/42

    CE 0123

    Certain products may not be approved for sale in all countries.

    Indications

    Is indicated augment or substitute for bone graft in nonloadbearing clinical applications

    Spine

    • Posterolateral Fusion

    Availability

    MBCP™ Sticks are available in:

    Pack of 2
    Pack of 4
    Pack of 2
    Pack of 4

    Related Products

    Back to Top

    Be contacted by our sales team to distribute our products!

    We will never give away, trade or sell your email address. You can unsubscribe at any time.

    Be contacted by our sales team to distribute our products!

    We will never give away, trade or sell your email address. You can unsubscribe at any time.

    HEALTH PROFESSIONALS ONLY
    This site is intended for health professionals.
    You must confirm that your are a health professional to browse this website.

    Do you confirm that you are a health professional?