Innovative and unique design
    Resorbable Composite sheath

    Osteotwin™ Sheath is designed to increase soft tissue fixation in ACL reconstruction surgery. Using Osteotwin™ Sheath allows fixation strength and graft protection.*
    Osteotwin™ Sheath is made of 75% of PLDLLA and 25% of MBCP™ Technology.

    Osteotwin™ Resorbable Sheath Design

    osteotwin resorbable sheath
    The thread of the resorbable sheath is specific to each screw diameter so as to systematically provide the maximum amount of contact between implant and bone.

    resorbable sheath average failure loads

    • ISO 13485
    • Read the instruction for use
    • Osteotwin™ is supplied sterile and CE-marked as a Class III Medical Device according to Directive EEC/93/42

    Daculsi, G., O. Laboux, et al. (2003). «Current state of the art of biphasic calcium phosphate bioceramics.» Journal of Materials Science: Materials in Medicine 14(3): 195-200. -More-
    Middleton, J. C. et al.; Biomaterials 21 (23), «Synthetic biodegradable polymers as orthopedic devices», 2000 2335-2346. -More-
    Suchenski, M., M. B. McCarthy, et al. (2010). «Material Properties and Composition of Soft-Tissue Fixation.» The Journal of Arthroscopic and Related Surgery 26(6): 821-831. -More-
    Uzel, A. P., E. Seris, et al. (2013). «Preclinical and clinical cases of new absorbable composite interference screws in osteoarticular surgery.» Key Engineering Materials 529-530: 325-330. -More-
    Kaeding, C., J. Farr, et al. (2005). «A Prospective Randomized Comparison of Bioabsorbable and Titanium Anterior Cruciate Ligament Interference Screws.» The Journal of Arthroscopic and Related Surgery 21(2): 147-151. -More-
    Hunt, J. A. and J. T. Callaghan (2008). «Polymer-hydroxyapatite composite versus polymer interference screws in anterior cruciate ligament reconstruction in a large animal model.» Knee Surgery, Sports Traumatology, Arthroscopy 16(7): 655-660. -More-
    Weiler, A., H. J. Windhagen, et al. (1998). «Biodegradable interference screw fixation exhibits pull-out force and stiffness similar to titanium screws.» The American journal of sports medicine 26(1): 119-126. -More-
    Weiler, A., R. F. Hoffmann, et al. (1998). «Hamstring tendon fixation using interference screws: a biomechanical study in calf tibial bone.» Arthroscopy: The Journal of Arthroscopic and Related Surgery 14(1): 29-37. -More-
    Black, J., (1988). «Does corrosion matter?» The Journal of Bone and Joint Surgery, 70-B(4): 517-520. -More-
    Bauer, J., Turgay, E., et al. (2010)., «Torsional stability of interference screws derived from bovine bone – a biomechanical study.» BMC Musculoskeletal Disorders 11: 82 -More-
    Uzel, P. A., G. Daculsi, et al, «Utilisation des coins de MBCP™ en traumatologie lors des fractures enfoncement (tibia proximal et distal, calcanéum) : double intérêt de comblement et d’étayage», 13ème Congrès de l’AOLF (2012) -More-
    R. Schouten, G. Hooper, The use of Bone substitute (Triosite) wedges in Medial Opening wedge high tibial osteotomies, 33 Patient clinical study, Journal of Bone & Joint Surgery, British Volume (2009) -More-
    Rouvillain, J.L., Lavalle, F., Pascal-Mousselard, H., Catonne, Y., Daculsi, G., Clinical, radiological and histological evaluation of biphasic calcium phosphate bioceramic wedges filling medial high tibial valgisation osteotomies., Knee (2009) -More-
    Rouvillain, J. L., Pascal-Mousselard, H., Lavalle, F, Garron E., Catonné Y., Daculsi G., MBCP Wedges performance during open medial tibial osteotomy, European conference on biomaterials (2006)
    Lavallé, F., H. Pascal-Mousselard, et al, Biphasic ceramic wedge and plate fixation with locked adjustable screws for open wedge tibial osteotomy, Revue de chirurgie orthopédique (2004) -More-
    * Data on files, Biomatlante

    To read the complete precautions, please refer to the Instructions for Use.
    The product must only be handled or implanted by trained qualified physicians having read the instructions for use.

    Not all products are registered or available in every country/region. Please check with Biomatlante representative for availability and further information.

    Indications

    • Resorbable sheath for ACL reconstruction

    Availability

    Diameter x Length in millimeters:
    7 x 8 mm
    9 x 10 mm

    Related Products

    Back to Top

    Be contacted by our sales team to distribute our products!

    We will never give away, trade or sell your email address. You can unsubscribe at any time.

    Be contacted by our sales team to distribute our products!

    We will never give away, trade or sell your email address. You can unsubscribe at any time.

    HEALTH PROFESSIONALS ONLY
    This site is intended for health professionals.
    You must confirm that your are a health professional to browse this website.

    Do you confirm that you are a health professional?